  1.                              TECHNICAL BULLETIN
  2.                                Bulletin 1-276
  3.  
  4. Date:  September 28, 1990
  5.  
  6. Mirroring Upgrade from NetWare v2.15 Rev. A to v2.15 Rev. C
  7.  
  8.      Several NetWare 286 v2.15 Rev. A disk mirroring limitations were 
  9.      addressed in v2.15 Rev. C (See Technical Bulletin 1-254).  Some of 
  10.      these limitations occur with the use of disk drives larger than 255MB;
  11.      NetWare 286 v2.15 did not fully support mirroring large drives until 
  12.      Revision C.  In cases where large mirrored drives experienced a 
  13.      failure or shutdown under v2.15 Rev. A and were subsequently 
  14.      remirrored, data corruption may have been introduced by the system.  
  15.      Normally, remirroring the disk drives after upgrading to v2.15 Rev. C 
  16.      will resolve this corruption.  In remote cases, data corruption may 
  17.      have been introduced on the primary drive.  In these extreme 
  18.      circumstances, it is advised that the disk drives be reinitialized 
  19.      and the data be restored from a reliable backup. 
  20.